Practical guidance on the use of capillary electrophoresis systems "Drops. Practical guide to the use of capillary electrophoresis systems "Drops of measurements

Type of equipment: from extent of capillary electrophoresis

Manufacturer: Lumeks

Series: Drops

Model: "Drop-105m"

Warranty on S. extents of capillary electrophoresis "drop-105m": 12 months.

Appointment of the device:

Systems of capillary electrophoresis "drop-105m" Have the most wide possibilities: auto implars, liquid cooling of the capillary, spectrophotometric detector, operation in automatic mode. These models along with the possibility of conventional measurements have a wide research potential, primarily due to the easily changeable length of the detection wave.

The "drop-105m" model differs from the "drop-104t" model by the presence of a spectrophotometric detector.

A deuterium lamp is used as a light source, and as a dispersing element - a diffraction monochromator with a spectral range of 190-380 nm and the width of the spectral interval of 20 nm. Such a range allows you to select the detection wavelength, the most sensitive to the analyzed substances, which facilitates the development of new techniques and, in many cases, reduces the detection limit.

Cooling the capillary - liquid with the task and control of the temperature of the coolant in the range from -10 ° C to + 30 ° C on the ambient temperature.

The method of input of test pressure or electrokinetic.

Sampling is automatic with auto-impeller on 10 input and 10 output tubes.

Washing capillary - automatic.

"Drop-105" is a device with the widest possible features. It saved the best quality of previous models - the liquid capillary cooling system, auto-implex, the ability to work in a programmable automatic mode: up to 15 analyzing programs are recorded in non-volatile memory. Each program may contain up to 60 steps, use cycles and call other programs. Programs can be created based on typical templates, edit and overwritten. Automatic mode frees user time, reduces the likelihood of errors during analyzes, increases the reproducibility of the results. Due to the deuterium lamp and the monochromator with a diffraction grid, the device can operate in any region of wavelengths from 190 to 380 nm. All this makes the "drop-105m" an indispensable device for research, both in the development of new techniques and in analytical practice.

"Drop-105m" today is the most recent model in the series "Drops". "Drop-105m" is fully controlled from the computer using a specialized software that allows you to additionally collect and process electrophoretic data. Other distinguishing features of this model are an advanced design of the cassette with a capillary, which allows you to quickly and reliably replace the capillary, as well as the possibility of registering the absorption spectra of the components of the analyzed sample. "Drop-105m" is certified for compliance with the requirements of the European Community Electrical Safety Directives 73/23 / EEC and 89/336 / EC.

Work procedure

"Drop-105m" is fully controlled from the computer using a specialized software, which, in addition to controlling the instrument, allows you to collect and process the electrophoretic data.

AREAS OF USE

analysis of environmental objects;

quality control of food and food raw materials;

control of the quality of feed, feeds, raw materials for their production, premix;

pharmaceuticals;

clinical biochemistry;

criminalistic examination;

chemical industry.

Examples of using the method in various fields are given in the book "Practical guide to the use of capillary electrophoresis systems" Drops ". Download the book (1.7 MB PDF).

Specifications:

Range of working lengths of the detection wave, nm

from 190 to 380

The limits of the allowed absolute error in the installation of the wavelength, nm

± 5.

Range of change of working voltage on the capillary, kV

from 1 to 25

The detection limit of benzoic acid (with a positive polarity of the high-voltage block) with a signal-to-noise / noise of 3: 1, μg / cm 3, not more than

The detection limit of chloride ions (with a negative polarity of the high-voltage block) with the signal / noise of 3: 1, μg / cm 3, not more than

The limit of the permissible relative average quadratic deviation (SKO) of the output signal along the peak area,%

Limit of a permitted relative average quadratic deviation (SKO) output signal for 8 hours of operation,%

Installation time of working mode, min, no more

Power supply systems from an AC voltage (220 ± 22) V, frequency (50 ± 1) Hz.

Power consumption consumed by the system, in × a, not more than:

Overall dimensions (d'Sh'v), mm, no more

420x570x360

Mass, kg, no more

Operating conditions:

ambient temperature, ° C

from 10 to 35

relative humidity (at 25 ° C),%, no more

atmospheric pressure, kPa

from 84 to 106.7

Average work on failure, h, not less

2500

Average service life, years, not less

Contents of delivery:

system of capillary electrophoresis "drop-105m". The package includes: droplet system, specialized Elforan® software, high voltage source with variable polarity; one cassette with the capillary; Zip; Eppendorf type test tubes; Reusable nozzle for filtering; filters;

spare cassette with a capillary and / or a special cassette with a capillary (for amino acids and vitamins, bromide and iodide ions), at the request of the customer;

microdosators at 10-100 and 100-1000 μl and tips to them;

computer with installed Windows-2000 / XP (at the request of the customer);

software "Multichrom", basic version 3.x;

sets for analysis (at the request of the customer).

* Specifications and instrument delivery kit can be changed by the manufacturer without notice.

Additional information can be obtained by contacting our specialists, by phone numbers specified in the "Contacts" section.

We deliver laboratory equipment throughout Russia by courier services and transport companies.

The "Drop®-105 / 105M" model differs from the "drop-104T / 104M" model by the presence of a spectrophotometric detector.
A deuterium lamp is used as a light source, and as a dispersing element - a diffraction monochromator with a spectral range of 190-380 nm and the width of the spectral interval of 20 nm. Such a range allows you to select the detection wavelength, the most sensitive to the analyzed substances, which facilitates the development of new techniques and, in many cases, reduces the detection limit.

  • Cooling the capillary is a liquid with the task and control of the temperature of the coolant (range from -10 ° C to + 30 ° C on the ambient temperature).
  • Method for entering test pressure or electrokinetic
  • Sampling - automatic with auto-impeller on 10 input and 10 output tubes
  • Washing Capillary - Automatic

"Drop-105" is a device with the widest possible features. It saved the best quality of previous models - the liquid capillary cooling system, auto-implex, the ability to work in a programmable automatic mode: up to 15 analyzing programs are recorded in non-volatile memory. Each program may contain up to 60 steps, use cycles and call other programs. Programs can be created based on typical templates, edit and overwritten. Automatic mode frees user time, reduces the likelihood of errors during analyzes, increases the reproducibility of the results. Due to the deuterium lamp and the monochromator with a diffraction grid, the device can operate in any region of wavelengths from 190 to 380 nm. All this makes "drop-105" an indispensable device for research in both the development of new techniques and analytical practices.

"Drop-105m" today is the most recent model in the series "Drops". "Drop-105m" is fully controlled from the computer using a specialized software that allows you to additionally collect and process electrophoretic data. Other distinguishing features of this model are an advanced design of the cassette with a capillary, which allows you to quickly and reliably replace the capillary, as well as the possibility of registering the absorption spectra of the components of the analyzed sample. "Drop-105m" is certified for compliance with the requirements of the European Community Electrical Safety Directives 73/23 / EEC and 89/336 / EC.

  • system of capillary electrophoresis "drop-105 / 105m". The package includes: a "drop" system, specialized software (for 105m), a high voltage source with a variable polarity; one cassette with the capillary; Zip; Eppendorf type test tubes; Reusable nozzle for filtering; Filters
  • spare cassette with a capillary and / or a special cassette with a capillary (for amino acids and vitamins, bromide and iodide ions)
  • microdoses for 10-100 and 100-1000 μl and tips to them
  • computer with Windows-2000 / XP installed (at the request of the customer)
  • software "Multihr" ("drop-105") version of 1.5x (for all models, except for "drop-104m" / "drop-105m"); The control version of 2.50x (only for models "drop-104m" / "drop-105m")
  • elforan® software ("drop-105m")
  • sets for analysis (at the request of the customer)

Work procedure:

"Drop-105" is controlled from the front panel using the built-in keyboard and display through the menu system, the result of the analysis is displayed on an external computer. Processing results are carried out using Multichrom®. It is possible to work in a programmable automatic mode, including the execution of a series of analyzes (cycles).
"Drop-105m" is fully controlled from the computer using a specialized software, which, in addition to controlling the instrument, allows you to collect and process the electrophoretic data.

Areas of use:

  • analysis of environmental objects
  • quality control of food products and food raw materials
  • quality control of feed, feed feed, raw materials for their production, premixes
  • pharmaceutics
  • clinical biochemistry
  • criminalistic examination
  • chemical industry

Installation conditions:

  • the presence in the laboratory of centrifuges, microdoses, bidistilletor

Service:

  • training in St. Petersburg or customer laboratory

Systems of capillary electrophoresis "drops®-105m"

  • State Register of the Russian Federation № 17727-11
  • State Registry of SI RB No. 03 09 0926 12
  • Kazakhstan State Registry No. KZ.02.03.04489-2012 / 17727-11
  • Declaration of Conformity TC RU D-RU.ME03.B00001
  • Code CNO 03.07.03.00.00
  • OKP 42 1540.
  • OKPD 33.20.53.145

The main distinguishing feature of the "drop-105m" model is spectrophotometric detection.

A deuterium lamp is used as a light source, and as a dispersing element - a diffraction monochromator with a spectral range of 190-380 nm and the width of the spectral interval of 20 nm. This range allows you to select the detection wavelength, the most sensitive to the target components, which facilitates the development of new techniques and in many cases reduces the detection limit.

"Drop-105M" is completely controlled from the computer using a specialized software that allows you to additionally collect and handle electrophoretic data.

The "drop-105m" system uses an improved design of the cassette with a capillary, which is even faster and more reliable to replace the capillary.

The device includes the possibility of registering the absorption spectra of the components of the analyzed sample.

"Drop-105m" is certified for compliance with the requirements of the European Community Electrical Safety Directives 73/23 / EEC and 89/336 / EC.

From the 4th quarter of 2014, the "drop-105m" comes with a high voltage source with a switchable polarity, which further simplifies the work procedure.

Optional possibility of washing the capillary at 2 atm. Allows the gel electrophoresis mode.

At the same time, the best qualities of previous models are saved in the "drop-105m" system:

  • Cooling the capillary - liquid. The selection of the temperature of the coolant depends on the ambient temperature and is possible in the range from minus 10 ° C to +30 ° C on the ambient temperature, but not lower than +5 ° C and not higher than +50 ° C.
  • The method of input of test pressure or electrokinetic.
  • AutoMempler on 10 input and 10 output tubes.
  • All procedures - from the input of samples before washing the capillary are made automatically in programming mode, which reduces the time and the likelihood of an error during analysis and improves the reproducibility of the results.

All this makes "drop-105m" by a convenient tool for both research in the development of new techniques and in analytical practice.

Areas of use:

  • analysis of environmental objects;
  • quality control of food and food raw materials;
  • quality control of drinks (alcoholic and non-alcoholic)
  • control of the quality of feed, feeds, raw materials for their production, premix;
  • pharmaceuticals;
  • clinical biochemistry;
  • criminalistic examination;
  • chemical industry.

Installation conditions:

  • the presence in the laboratory of centrifuges, microdoses, bidistilletor.

System of capillary electrophoresis with spectrophotometric detector, autosampler and liquid cooling of the capillary. Fully controlled from the computer.

Model Drop-105m It differs from the model of drop-104m by the presence of a spectrophotometric detector.

A deuterium lamp is used as a light source, and as a dispersing element - a diffraction monochromator with a spectral range of 190-380 nm and the width of the spectral interval of 20 nm. Such a range allows you to select the detection wavelength, the most sensitive to the analyzed substances, which facilitates the development of new techniques and, in many cases, reduces the detection limit.

  • Cooling the capillary is a liquid with the task and control of the temperature of the coolant (range from -10 ° C to + 30 ° C on the ambient temperature).
  • The method of input of test pressure or electrokinetic.
  • Sampling - automatic with autosampler on 10 input and 10 output tubes.
  • Washing capillary - automatic.

Drop-105 To date, the most recent model in the series of drops ®. Drop-105m It is fully controlled from the computer using a specialized software that allows you to additionally collect and process electrophoretic data. Other distinguishing features of this model are an advanced design of the cassette with a capillary, which allows you to quickly and reliably replace the capillary, as well as the possibility of registering the absorption spectra of the components of the analyzed sample. Drop-105m Certified for compliance with the requirements of the European Community Electrical Safety Directives 73/23 / EEC and 89/336 / EC.

Areas of use:

  • analysis of environmental objects;
  • quality control of food and food raw materials;
  • control of the quality of feed, feeds, raw materials for their production, premix;
  • pharmaceuticals;
  • clinical biochemistry;
  • criminalistic examination;
  • chemical industry.

Specifications

Photometric detector 190-380 Nm
High voltage block permanent voltage of 1-25 kV, with 1kV increments,
Replaceable polarity, current 0-200 μA
Putting hydrodynamic or electrokinetic
Sampling automatic with two autosampleplates on 10 input and
10 output tubes
Flushing at a constant pressure of 1000 mbar
Capillary quartz (length 30-100 cm, inner diameter 50 or 75 microns)
Cooling the capillary liquid with the task and control of the temperature of the coolant
(range from -10 ° C to + 30 ° C on ambient temperature)
The ability to task and / or change
parameters during analysis
analysis time, wavelength, pressure, temperature, voltage
Food 187-242 V, 50/60 Hz
Power consumption 200 W.
Gabarits. 500 x 500 x 500 mm
Weight 30 kg

Drop-105M system for capillary electrophoresis It differs from the model of droplets-104 t / 104 m by the presence of a spectrophotometric detector.

A deuterium lamp is used as a light source, and as a dispersing element - a diffraction monochromator with a spectral range of 190-380 nm and the width of the spectral interval of 20 nm. Such a range allows you to select the detection wavelength, the most sensitive to the analyzed substances, which facilitates the development of new techniques and, in many cases, reduces the detection limit. Cooling the capillary - liquid with the task and control of the temperature of the coolant (range from -10 ° C to +30 ° C on the ambient temperature). The method of input of test pressure or electrokinetic. Sampling is automatic with auto-impeller on 10 input and 10 output tubes. Washing capillary - automatic.

Drop-105 M- device with the widest possible features. It saved the best quality of previous models - the liquid capillary cooling system, auto-implex, the ability to work in a programmable automatic mode: up to 15 analyzing programs are recorded in non-volatile memory. Each program may contain up to 60 steps, use cycles and call other programs. Programs can be created based on typical templates, edit and overwritten. Automatic mode frees user time, reduces the likelihood of errors during analyzes, increases the reproducibility of the results. Due to the deuterium lamp and the monochromator with a diffraction grid, the device can operate in any region of wavelengths from 190 to 380 nm. All this makes the "drop-105 M" an indispensable instrument for research work both in the development of new techniques and in analytical practice.

Drop-105 m to date is the most recent model in a series of drops. Drop-105 m is fully controlled from the computer using a specialized software that allows you to additionally collect and process electrophoretic data. Other distinguishing features of this model are an advanced design of the cassette with a capillary, which allows you to quickly and reliably replace the capillary, as well as the possibility of registering the absorption spectra of the components of the analyzed sample. "Drop-105 M" is certified for compliance with the requirements of the European Community Electrical Safety Directives 73/23 / EEC and 89/336 / EC.


Work procedure:

Drop-105 m is fully controlled from the computer using a specialized software that, in addition to controlling the instrument, allows you to collect and process electrophoretic data.

Areas of use:

Analysis of environmental objects
- quality control of food and food raw materials
- Quality control of feed, feed, raw materials for their production, premixes
- Pharmaceuticals
- Clinical biochemistry
- Criminalistic examination
- Chemical industry